Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Microorganisms ; 11(5)2023 May 07.
Article in English | MEDLINE | ID: covidwho-20242988

ABSTRACT

Due to the high reproduction rate of COVID-19, it is important to identify and isolate infected patients at the early stages of infection. The limitations of current diagnostic methods are speed, cost, and accuracy. Furthermore, new viral variants have emerged with higher rates of infectivity and mortality, many with mutations at various primer binding sites, which may evade detection via conventional PCR kits. Therefore, a rapid method that is sensitive, specific, and cost-effective is needed for a point-of-care molecular test. Accordingly, we developed a rapid molecular SARS-CoV-2 detection kit with high specificity and sensitivity, RT-PCR, taking advantage of the loop-mediated isothermal amplification (LAMP) technique. Four sets of six primers were designed based on conserved regions of the SARS-CoV-2 genome: two outer, two inner and two loop primers. Using the optimized protocol, SARS-CoV-2 genes were detected as quickly as 10 min but were most sensitive at 30 min, detecting as little as 100 copies of template DNA. We then coupled the RT-LAMP with a lateral flow dipstick (LFD) for multiplex detection. The LFD could detect two genic amplifications on a single strip, making it suitable for multiplexed detection. The development of a multiplexed RT-LAMP-LFD reaction on crude VTM samples would be suitable for the point-of-care diagnosis of COVID-19 in diagnostic laboratories as well as in private homes.

2.
Front Vet Sci ; 9: 1059934, 2022.
Article in English | MEDLINE | ID: covidwho-2241830

ABSTRACT

Bovine coronavirus (BCoV) is a major cause of infectious disease in cattle, causing huge economic losses to the beef and dairy industries worldwide. BCoV can infect humans and multiple other species of animals. A rapid, reliable, and simple test is needed to detect BCoV infection in suspected farms. In this study, we developed a novel multienzyme isothermal rapid amplification (MIRA) and lateral flow dipstick (LFD) combination assay, targeting a highly conserved region of the viral nucleocapsid (N) gene for BCoV detection. The MIRA-LFD assay was highly specific and sensitive, comparable to a published reverse transcription quantitative PCR (RT-qPCR) assay for BCoV detection. Compared with the published RT-qPCR assay, the κ value of the MIRA-LFD assay in the detection of 192 cattle clinical samples was 0.982. The MIRA-LFD assay did not require sophisticated instruments and the results could be observed with eyes. Our results showed that the MIRA-LFD assay was a useful diagnostic tool for rapid on-site detection of BCoV.

3.
Appl Microbiol Biotechnol ; 106(4): 1651-1661, 2022 Feb.
Article in English | MEDLINE | ID: covidwho-1888851

ABSTRACT

Feline calicivirus (FCV) has a single-stranded, positive-sense RNA genome, and it is responsible for many infectious respiratory diseases in cats. In addition, more worryingly, highly virulent strains of FCV can cause high mortality in felines. Therefore, a rapid and reliable diagnosis tool plays an important role in controlling the outbreak of FCV. In this study, enzymatic recombinase amplification (ERA) assay combined with lateral flow dipstick (LFD) was developed for the detection of FCV, targeting a relatively conversed position of FCV-ORF1. The results showed that the optimal reaction condition was at 40 °C for 30 min. ERA-LFD method was highly sensitive with the detection limit as low as 3.2 TCID50 of FCV RNA per reaction. The specificity analysis demonstrated no cross-reactivity with feline parvovirus (FPV), feline herpesvirus (FHV) and feline infectious peritonitis virus (FIPV). ERA-LFD was highly repeatable and reproducible, with the intra-assay and inter-assay coefficients of variation for this method both less than 7%. The general test showed that all the recombinant plasmids with known mutant sites and FCV strains with different mutant sites stored in our laboratory were all detected by this method. Of the 23 samples, 14 samples were tested positive for FCV by ERA-LFD and RT-qPCR, respectively. In summary, ERA-LFD assay was a fast, accurate and convenient diagnosis tool for the detection of FCV. KEY POINTS: • The detection principle of ERA-LFD was introduced. • Almost all the currently known FCV strains can be detected. • ERA-LFD is easy to operate and can be used for field detection.


Subject(s)
Caliciviridae Infections , Calicivirus, Feline , Communicable Diseases , Animals , Caliciviridae Infections/diagnosis , Caliciviridae Infections/veterinary , Calicivirus, Feline/genetics , Cats , Real-Time Polymerase Chain Reaction , Recombinases
4.
Virulence ; 13(1): 1471-1485, 2022 12.
Article in English | MEDLINE | ID: covidwho-2017508

ABSTRACT

Porcine deltacoronavirus (PDCoV) is an emerging enteropathogen causing severe diarrhoea, dehydration, and death in nursing piglets and enormous economic losses for the global swine industry. Furthermore, it can infect multiple animal species including humans. Therefore, a rapid, definitive diagnostic assay is required for the effective control of this zoonotic pathogen. To identify PDCoV, we developed a nucleic acid detection assay combining reverse transcription recombinase-aided amplification (RT-RAA) with a lateral flow dipstick (LFD) targeting the highly conserved genomic region in the ORF1b gene. The RT-RAA-LFD assay exhibited good PDCoV detection reproducibility and repeatability and could be completed within 11 min. Ten minutes at 40 °C was required for nucleic acid amplification and 1 min at room temperature was needed for the visual LFD readout. The assay specifically detected PDCoV and did not cross-react with any other major swine pathogens. The 95% limit of detection (LOD) was 3.97 median tissue culture infectious dose PDCoV RNA per reaction. This performance was comparable to that of a reference TaqMan-based real-time RT-PCR (trRT-PCR) assay for PDCoV. Of 149 swine small intestine, rectal swab, and serum samples, 71 and 75 tested positive for PDCoV according to RT-RAA-LFD and trRT-PCR, respectively. The diagnostic coincidence rate for both assays was 97.32% (145/149) and the kappa value was 0.946 (p < 0.001). Overall, the RT-RAA-LFD assay is a user-friendly diagnostic tool that can rapidly and visually detect PDCoV.


Subject(s)
Nucleic Acids , Recombinases , Animals , Deltacoronavirus , Humans , Nucleic Acid Amplification Techniques , Recombinases/genetics , Recombinases/metabolism , Reproducibility of Results , Reverse Transcription , Sensitivity and Specificity , Swine
5.
Front Cell Infect Microbiol ; 11: 678703, 2021.
Article in English | MEDLINE | ID: covidwho-1505766

ABSTRACT

In December 2019, a severe acute respiratory syndrome caused by SARS-CoV-2 spread rapidly worldwide. Portable nucleic acid tests of SARS-CoV-2 are critically important for diagnostics. In this study, we used an isothermal amplification method-Multienzyme Isothermal Rapid Amplification (MIRA)-for rapid detection of SARS-CoV-2. We designed the primers and probes in ORF1ab and N gene of SARS-CoV-2. The amplicons could be monitored by lateral flow dipsticks (LFDs). The reaction temperature, time, concentrations of primers and probes, and working volume were optimized. Four commercial swab collection buffers were used to test the amplification efficacy of our assay without RNA extraction. Our assay was able to amplify duplex targets of SARS-CoV-2 in one single reaction using one-step RT-MIRA. The assay worked well in a low volume of 10 µl at 38°C for 20 min. Using three collection buffers without guanidinium, our assay was able to amplify efficaciously without RNA extraction. The 95% limit of detection (LoD) of the RT-MIRA assay was 49.5 (95% CI, 46.8-52.7) copies/ml for ORF1ab gene and 48.8 (95% CI, 46.5-52.6) copies/ml for N gene. There is no cross-reaction with other human respiratory pathogens, such as SARS-CoV, MERS-CoV, influenza A virus, influenza B virus, human adenovirus, respiratory syncytial virus, human parainfluenza virus, and coronavirus 229E in our assay. The precision evaluation revealed that the C50-20% to C50+20% range bounds the C5-C95 interval. This assay also showed high anti-interference ability. The extraction-free RT-MIRA and qPCR detection results of 243 nucleic acid specimens from suspected patients or national references showed a 100.0% (95% confidence interval, 94.2%-100.0%) positive predictive value and a 100.0% (95% confidence interval, 92.7%-100.0%) negative predictive value. Compared with qPCR, the kappa value of the two assays was 1.00 (P < 0.0001). In conclusion, we provide a portable and visualized method for detection of SARS-CoV-2 without RNA extraction, allowing its application in SARS-CoV-2 on-site detection.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , Nucleic Acid Amplification Techniques , Point-of-Care Testing , RNA, Viral/genetics , Reverse Transcription
6.
Front Cell Infect Microbiol ; 11: 613304, 2021.
Article in English | MEDLINE | ID: covidwho-1088903

ABSTRACT

Background: The emerging Coronavirus Disease-2019 (COVID-19) has challenged the public health globally. With the increasing requirement of detection for SARS-CoV-2 outside of the laboratory setting, a rapid and precise Point of Care Test (POCT) is urgently needed. Methods: Targeting the nucleocapsid (N) gene of SARS-CoV-2, specific primers, and probes for reverse transcription recombinase-aided amplification coupled with lateral flow dipstick (RT-RAA/LFD) platform were designed. For specificity evaluation, it was tested with human coronaviruses, human influenza A virus, influenza B viruses, respiratory syncytial virus, and hepatitis B virus, respectively. For sensitivity assay, it was estimated by templates of recombinant plasmid and pseudovirus of SARS-CoV-2 RNA. For clinical assessment, 100 clinical samples (13 positive and 87 negatives for SARS-CoV-2) were tested via quantitative reverse transcription PCR (RT-qPCR) and RT-RAA/LFD, respectively. Results: The limit of detection was 1 copies/µl in RT-RAA/LFD assay, which could be conducted within 30 min at 39°C, without any cross-reaction with other human coronaviruses and clinical respiratory pathogens. Compared with RT-qPCR, the established POCT assay offered 100% specificity and 100% sensitivity in the detection of clinical samples. Conclusion: This work provides a convenient POCT tool for rapid screening, diagnosis, and monitoring of suspected patients in SARS-CoV-2 endemic areas.


Subject(s)
COVID-19 Nucleic Acid Testing/methods , COVID-19/diagnosis , Real-Time Polymerase Chain Reaction/methods , SARS-CoV-2/genetics , COVID-19/virology , COVID-19 Nucleic Acid Testing/instrumentation , Coronavirus Nucleocapsid Proteins/genetics , DNA Primers/genetics , Humans , Phosphoproteins/genetics , Point-of-Care Testing , RNA, Viral/genetics , Real-Time Polymerase Chain Reaction/instrumentation , Recombinases/metabolism , Reverse Transcription , SARS-CoV-2/isolation & purification , Sensitivity and Specificity
7.
BMC Vet Res ; 16(1): 130, 2020 May 07.
Article in English | MEDLINE | ID: covidwho-197648

ABSTRACT

BACKGROUND: Porcine Deltacoronavirus (PDCoV) is a newly emerging Coronavirus that was first identified in 2012 in Hong Kong, China. Since then, PDCoV has subsequently been reported worldwide, causing a high number of neonatal piglet deaths and significant economic losses to the swine industry. Therefore, it is necessary to establish a highly sensitive and specific method for the rapid diagnosis of PDCoV. RESULTS: In the present study, a highly sensitive and specific diagnostic method using recombinase polymerase amplification combined with a lateral flow dipstick (LFD-RPA) was developed for rapid and visual detection of PDCoV. The system can be performed under a broad range of temperature conditions from 10 to 37 °C, and the detection of PDCoV can be completed in 10 min at 37 °C. The sensitivity of this assay was 10 times higher than that of conventional PCR with a lower detection limit of 1 × 102 copies/µl of PDCoV. Meanwhile, the LFD-RPA assay specifically amplified PDCoV, while there was no cross-amplification with other swine-associated viruses, including Porcine epidemic diarrhea virus (PEDV), Transmissible gastroenteritis virus (TGEV), Porcine kobuvirus (PKoV), Foot and mouth disease virus (FMDV), Porcine reproductive and respiratory syndrome virus (PRRSV), Porcine circovirus type 2 (PCV2), Classical swine fever virus (CSFV) and Seneca valley virus (SVV). The repeatability of the test results indicated that this assay had good repeatability. In addition, 68 clinical samples (48 fecal swab specimens and 20 intestinal specimens) were further tested by LFD-RPA and RT-PCR assay. The positive rate of LFD-RPA clinical samples was 26.47% higher than that of conventional PCR (23.53%). CONCLUSIONS: The LFD-RPA assay successfully detected PDCoV in less than 20 min in this study, providing a potentially valuable tool to improve molecular detection for PDCoV and to monitor the outbreak of PDCoV, especially in low-resource areas and laboratories.


Subject(s)
Coronavirus/isolation & purification , Polymerase Chain Reaction/methods , Recombinases/metabolism , Serologic Tests/veterinary , Animals , Coronavirus Infections/diagnosis , Coronavirus Infections/veterinary , Coronavirus Infections/virology , Nucleic Acid Amplification Techniques/methods , Sensitivity and Specificity , Serologic Tests/methods , Swine , Swine Diseases/virology
SELECTION OF CITATIONS
SEARCH DETAIL